首页 / 漏洞情报库
🛡️ 漏洞情报库(CVE 查询与修复方法)
每日采集 NVD / CISA / 微软等主流漏洞源的 CVE 信息,含漏洞说明、受影响产品、修复方法(补丁/升级版本)。支持按 CVE 号、关键词、风险等级、是否在野、发布时间筛选。
📌 最近漏洞情报周报(每周一篇)
共 45356 条漏洞
| CVE | 等级 | CVSS | 发布时间 | 说明 | 受影响 | 修复方法 |
|---|---|---|---|---|---|---|
| CVE-2026-82786 | MEDIUM | 6.3 | 2026-09-14 | Insufficiently protected credentials issue exists in Remote I/O Coupler Unit (Server Type) | Contec Co., Ltd. Remote I/O Coupler Unit | 受影响版本 < 1.82,请升级到修复版本。 |
| CVE-2026-82785 | MEDIUM | 4.3 | 2026-09-14 | Stack-based buffer overflow vulnerability exists in Remote I/O Coupler Unit (Server Type) | Contec Co., Ltd. Remote I/O Coupler Unit | 受影响版本 < 1.82,请升级到修复版本。 |
| CVE-2026-82784 | MEDIUM | 6.5 | 2026-09-14 | Missing authentication for critical function vulnerability exists in Remote I/O Coupler Un | Contec Co., Ltd. Remote I/O Coupler Unit | 受影响版本 < 1.82,请升级到修复版本。 |
| CVE-2026-82783 | MEDIUM | 4.2 | 2026-09-14 | Plaintext storage of a password issue exists in CONPROSYS nano Series . If this vulnerabil | Contec Co., Ltd. Remote I/O Coupler Unit | 受影响版本 < 1.61,请升级到修复版本。 |
| CVE-2026-82782 | MEDIUM | 4.3 | 2026-09-14 | Out-of-bounds write vulnerability exists in CONPROSYS nano Series. Receiving a specially c | Contec Co., Ltd. Remote I/O Coupler Unit | 受影响版本 < 1.61,请升级到修复版本。 |
| CVE-2026-82781 | MEDIUM | 5.4 | 2026-09-14 | Cross-site scripting vulnerability exists in CONPROSYS nano Series. If this vulnerability | Contec Co., Ltd. Remote I/O Coupler Unit | 受影响版本 < 1.61,请升级到修复版本。 |
| CVE-2026-82780 | HIGH | 8.8 | 2026-09-14 | Unrestricted upload of file with dangerous type issue exists in CONPROSYS TM Series. If a | Contec Co., Ltd CPS-TM341G5MB-ADSC1-931, | 受影响版本 < 2.19,请升级到修复版本。 |
| CVE-2026-82779 | HIGH | 8.8 | 2026-09-14 | Improper neutralization of special elements used in an OS command ('OS Command Injection') | Contec Co., Ltd CPS-TM341G5MB-ADSC1-931, | 受影响版本 < 2.19,请升级到修复版本。 |
| CVE-2026-82778 | MEDIUM | 4.3 | 2026-09-14 | An exposure of information through directory listing issue exists in CONPROSYS PAC Series. | Contec Co., Ltd. Integrated Type CPS-PC3 | 受影响版本 < 3.0.0,请升级到修复版本。 |
| CVE-2026-82777 | HIGH | 8.8 | 2026-09-14 | Improper neutralization of special elements used in an OS command ('OS Command Injection') | Contec Co., Ltd. Integrated Type CPS-PC3 | 受影响版本 < 3.0.0,请升级到修复版本。 |
| CVE-2026-82776 | MEDIUM | 6.1 | 2026-09-14 | Cross-site scripting vulnerability exists in CONPROSYS PAC Series. If this vulnerability i | Contec Co., Ltd. Integrated Type CPS-PC3 | 受影响版本 < 3.0.0,请升级到修复版本。 |
| CVE-2026-82775 | MEDIUM | 4.3 | 2026-09-14 | An exposure of information through directory listing issue exists in CONPROSYS M2M Gateway | Contec Co., Ltd. M2M Gateway Integrated | 受影响版本 < 4.1.0,请升级到修复版本。 |
| CVE-2026-82774 | HIGH | 8.8 | 2026-09-14 | Improper neutralization of special elements used in an OS command ('OS Command Injection') | Contec Co., Ltd. M2M Gateway Integrated | 受影响版本 < 4.1.0,请升级到修复版本。 |
| CVE-2026-82773 | MEDIUM | 6.1 | 2026-09-14 | Cross-site scripting vulnerability exists in CONPROSYS M2M Gateway Series and CONPROSYS M2 | Contec Co., Ltd. M2M Gateway Integrated | 受影响版本 < 4.1.0,请升级到修复版本。 |
| CVE-2026-82772 | HIGH | 8.8 | 2026-09-14 | Buffer overflow vulnerability exists in Contec EC1000 series. If a remote attacker sends a | Contec Co., Ltd. ECE1000, Contec Co., Lt | 受影响版本 < 1.02,请升级到修复版本。 |
| CVE-2026-82771 | MEDIUM | 5.4 | 2026-09-14 | Cross-site scripting vulnerability exists in Contec EC1000 series. If this vulnerability i | Contec Co., Ltd. ECE1000, Contec Co., Lt | 受影响版本 < 1.02,请升级到修复版本。 |
| CVE-2026-82770 | HIGH | 8.8 | 2026-09-14 | Buffer overflow vulnerability exists in Contec RP-WAH-SR Series. If a remote attacker send | Contec Co., Ltd. RP-WAH-SR1, Contec Co., | 受影响版本 < 1.02,请升级到修复版本。 |
| CVE-2026-82769 | MEDIUM | 5.4 | 2026-09-14 | Cross-site scripting vulnerability exists in Contec RP-WAH-SR Series. If this vulnerabilit | Contec Co., Ltd. RP-WAH-SR1, Contec Co., | 受影响版本 < 1.02,请升级到修复版本。 |
| CVE-2026-82768 | HIGH | 8.1 | 2026-09-14 | Path traversal vulnerability exists in SGA1000. If this vulnerability is exploited, arbitr | Contec Co., Ltd. SGA1000 | 受影响版本 < 1.02,请升级到修复版本。 |
| CVE-2026-82767 | MEDIUM | 5.2 | 2026-09-14 | Cross-site scripting vulnerability exists in SGA1000. If this vulnerability is exploited, | Contec Co., Ltd. SGA1000 | 受影响版本 < 1.02,请升级到修复版本。 |
💡 说明:数据源为 NVD、CISA(在野利用)、微软等官方公开情报,每日自动采集。中文源 CNNVD/CNVD 受官方接口限制暂未接入,描述以英文原版为准,可点击 CVE 号查看详情与官方参考链接。修复方法含补丁/升级版本线索,具体请以厂商官方公告为准。